Indicate the minimum cable size recommended for a 50A breaker installed on a 115/230V system. 

Assumptions:

  • Cable Type - Single-core 70 deg C thermoplastic insulated cables, non-armoured, with or without sheath
  • Installation is enclosed in conduit on a wall or in trunking etc.

TTS 171 Part 1:  Table 4D1A

0%
0%
0%
0%
100%
0%
View this question

TTS 171: Part 1 Clause 9.12.1 states that "In residential buildings receptacle outlets shall be installed in each room, except bathrooms, such that no point, measured horizontally along the floor line of any wall, is more than 1.8 metres (6 ft) from a receptacle outlet."

For a room of length of 14 feet and width 13 feet, with a 3 ft doorway, determine the minimum number of receptacle outlets required? 

100%
0%
0%
0%
0%
View this question

The illustration below shows the circuit connections for a 230V 50A receptacle. If the live and neutral conductors are 10 mm squared, what is the size of the ground conductor?

Power receptacle circuit for an electric range

0%
0%
0%
100%
0%
0%
View this question

A contractor wishes to implement a fixed cable, electric power and lighting installation for the wiring inside a house. Select an appropriate cable specification number from the options below. You may consult Table D.1B below, for further information on the specification numbers.

TTS171 Part 1: Table D.1B piece 1

TTS171 Part 1: Table D.1B piece 2

100%
0%
0%
0%
0%
View this question

An electric range has the following specifications

  • Voltage: 230V
  • Current: 40 A
  • Power: 13.6 kW

In addition, the electrical installation will have the following features

  1. 50A DP circuit breaker
  2. Cable type: Single-core 70 deg C thermoplastic insulated cables, non-armoured, with or without sheath
  3. Cable Size: 10 mm squared
  4. Cable Installation method: Enclosed in conduit on a wall  or trunking etc.
  5. Length of cable run: 59 feet

Consult table below and calculate the expected voltage drop for the installation.

Voltage drop per A per m

View this question

A 6000 BTU air conditioning unit has the following specifications

  • Voltage: 115 V
  • Current: 4.9 A
  • Power: 540 W

In addition, the electrical installation will have the following features

  1. NEMA 5-15R receptacle and 15A SP circuit breaker
  2. Cable type: Single-core 70 deg C thermoplastic insulated cables, non-armoured, with or without sheath
  3. Cable Installation method: Enclosed in conduit on a wall  or trunking etc
  4. Length of cable run: 23 feet

Current carrying capacity

Voltage drop per A per m

Considering the voltage drops, what is the minimum recommended cable size for this installation?

0%
0%
0%
0%
100%
0%
View this question

A contractor has purchased a SPDT switch for residential wiring. How many cable termination screws does this switch have?

0%
100%
0%
0%
0%
View this question

Indicate the minimum cable size recommended for a 20A breaker installed on a 115/230V system. 

Assumptions:

  • Cable Type - Single-core 70 deg C thermoplastic insulated cables, non-armoured, with or without sheath
  • Installation is enclosed in conduit on a wall or in trunking etc.

TTS 171 Part 1:  Table 4D1A

0%
0%
0%
100%
0%
0%
View this question

Indicate the minimum cable size recommended for a 15A breaker installed on a 115/230V system. 

Assumptions:

  • Cable Type - Single-core 70 deg C thermoplastic insulated cables, non-armoured, with or without sheath
  • Installation is enclosed in conduit on a wall or in trunking etc.

TTS 171 Part 1:  Table 4D1A

0%
0%
0%
0%
100%
0%
View this question

A contractor has purchased a DPST switch for residential wiring. How many cable termination screws does this switch have?

100%
0%
0%
0%
0%
View this question